2
20MSERIES
E20M Series
(Manual Operation)
Installation and Operation Manual
234090-1
Contents List
E20M Series Turbofan Convection Ovens.
Model Numbers Covered in this Manual
E22M3 - Turbofan Oven - 3 Tray Convection Oven.
E23M3 - Turbofan Oven - 3 Tray Convection Oven.
E27M2 - Turbofan Oven - 2 Tray Convection Oven.
E27M3 - Turbofan Oven - 3 Tray Convection Oven.
E28M4 - Turbofan Oven - 4 Tray Convection Oven.
Introduction........................................................................................................... 2
Safety Information
Specifications......................................................................................................... 3
Installation............................................................................................................. 4
Installation Requirements
Unpacking
Location
Clearances
Stand Mounted Ovens
Electrical Connection
Positioning and Levelling of Oven
Initial Start-Up
Operation ............................................................................................................... 6
Operation Guide
Oven Control Panel
Description of Controls
Using the Oven
Cleaning ................................................................................................................. 7
Cleaning Guidelines
Oven Cleaning
Fault Finding ........................................................................................................ 10
Electrical Schematics ........................................................................................... 11
Replacement Parts List ........................................................................................ 13
Introduction
Before using your new oven, please read this instruction
This manual must be kept by the owner for future
reference.
manual carefully, pay particular attention to any information
labelled ‘WARNING’, ‘CAUTION’, ‘IMPORTANT’ or
‘NOTE’ in this manual.
A record of the Date of Purchase, Date of Installation
and Serial Number of the oven should be recorded in
the area provided below.
The serial number of this oven can be found on the
Technical Data Plate located on the front right hand
side panel, see diagram in ‘Installation Section’.
Indicates a hazardous situation
which, if not avoided, will result in
death or serious injury.
Warning
Caution
Indicates a hazardous situation
which, if not avoided, will result in
minor or moderate injury.
Model Number:
Serial Number:
Dealer:
If you are unsure of any aspect of the installation,
instructions or performance of your oven, contact your
TURBOFAN dealer promptly. In many cases a phone call
could answer your question.
Service Provider:
Should you contact your TURBOFAN dealer on any matter
concerning this oven, please have the information provided
opposite, readily available.
Date Purchased:
Date Installed:
Safety Information
For your safety, please pay attention to the following symbols
marked on the appliance.
- Risk of electric shock.
No user serviceable parts inside.
Qualified service person access only.
Disconnect from power before servicing.
2
Specifications
E22M3
E23M3
E27M2 / E27M3
E28M4
Oven Tray Details
Oven Power Ratings
Tray Capacity
Tray Spacing
3 x EN 2/3 Tray
3 x US ½ Pan
110-120V, 1P+N+E, 60HZ, 1.5 kW
220-240V, 1P+N+E, 50/60HZ, 2.0 kW
70 mm / 2 3/4”
E22M3
E23M3
E22M3
E23M3
208V,
220V,
1P+N+E, 50-60 HZ, 2.7 kW
1P+N+E, 50-60 HZ, 3.0 kW
3 x EN 2/3 Tray
3 x US ½ Pan
85 mm / 3 1/3”
230-240V, 1P+N+E, 50-60 HZ, 3.0 kW
208V,
220V,
1P+N+E, 50-60HZ, 2.7kW
1P+N+E, 50-60HZ, 3.0kW
3 x EN 600 x 400 mm Tray
3 x US Full Pan
85 mm / 3 1/3”
85 mm / 3 1/3”
76 mm / 3 ”
E27M2
E27M3
E28M4
E27M2
E27M3
E28M4
230-240V, 1P+N+E, 50-60HZ, 3.0kW
208V,
220V,
1P+N+E, 50-60HZ, 4.2kW
1P+N+E, 50-60HZ, 4.7kW
3 x EN 600 x 400 mm Tray
3 x US Full Pan
230-240V, 1P+N+E, 50-60HZ, 4.7kW
208V,
220V,
1P+N+E, 50-60HZ, 5.4kW
1P+N+E, 50-60HZ, 6.0kW
4 x EN 600 x 400 mm Tray
4 x US Full Pan
230-240V, 1P+N+E, 50-60HZ, 6.0kW
3
Installation
Installation Requirements
Important:
•
•
•
Installation shall comply with local electrical, health and safety requirements.
It is most important that this oven is installed correctly and that oven operation is correct before use.
If you have any questions regarding the proper installation and / or operation of this oven, please contact your local
Turbofan distributor.
Electrical Power
Rating
Oven
Serial Number
Oven
Model Number
Current Draw
MOFFAT LIMITED
)
MODEL
CODE
SERIAL
LOT
E22M3
USE22M3
xxxxxx
CHRISTCHURCH
(
NEW ZEALAND
yywwxxx
*******
A @
V a.c.
115
12.0
110-120 V a.c. 50-60 Hz
1.5 kW
1P+N+E
THIS APPLIANCE MUST BE EARTHED / GROUNDED
THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE WITH CURRENT
REGULATIONS AND USED ONLY IN A WELL-VENTILATED SPACE. REFER TO THE
INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE.
Technical Data Plate - Data and Location
(example only)
Unpacking
Clearances
1. Remove all packaging and transit protection including
all protective plastic coating from the exterior stainless
steel panels.
To ensure correct ventilation for the motor and controls,
the following minimum installation clearances are to be
adhered to:-
2. Check the oven and supplied parts for damage. Report
any damage immediately to the carrier and distributor.
3. Check that the following parts have been supplied with
your oven:-
Top
Rear
Left-hand side
Right-hand side
100 mm / 4”.
25 mm / 1”.
25 mm / 1”.
25 mm / 1”.
4 x Leg Adjustable.
Important:
4. Report any deficiencies to the distributor who supplied
your oven.
5. Securely fit the 4 legs supplied with the oven.
The vent located at the top (E22 Ovens) or rear (Other 20
Series Ovens) of the oven must NOT be obstructed.
Oven Vent Location
E23, E27, E28 Ovens
6. Check that the available electrical supply is correct to
that shown on the Technical Data Plate located on the
front right hand side panel.
Oven Vent Location
E22 Ovens
•
Refer to ‘Specifications’ section, ‘Oven
Specifications Tables’.
Location
1. Position the oven in its approximate working position.
2. The unit should be positioned so that the control panel
and oven shelves are easily reachable for loading and
unloading.
Stand Mounted Oven
For ovens that are to be mounted to a stand, the oven feet
are used to level the oven on the stand. Refer to the
instructions supplied with separately ordered stands for
mounting details.
4
Installation
Electrical Connection
Warning
Positioning and Levelling of Oven
1. Correctly locate the oven into its final operating position
and using a spirit level, adjust the legs so that the oven
is level and at the correct height.
This oven must be earthed / grounded.
If the supply cord is damaged, it must be replaced by a
suitably qualified person in order to avoid a hazard.
2. Adjust the oven feet to level the oven.
Initial Start-Up
Each oven should be connected to an adequately protected
power supply and an isolation switch mounted adjacent to,
but not behind the oven and must be readily accessible to
the operator. This switch must be clearly marked and
readily accessible in case of fire.
Before using the new oven;
1. For first time use of the oven, operate the oven for
about 1 hour at 200°C / 400°F to remove any fumes or
odours which may be present.
2. Please refer to the Operation Section of this manual for
details on how to correctly operate and shutdown the
oven.
Check the electricity supply is correct to as shown on the
Technical Data Plate on the front right hand corner of the
oven side panel.
Ovens Supplied with Cordsets (E22M3, E23M3, E27M2, E27M3)
1. Ensure that the oven is fitted with the appropriate
power cord and plug.
NOTE: For non USA / Canada E27M3 Ovens only,
ovens will be supplied with a bare cord only.
An appropriate plug must be supplied and
fitted by a suitably qualified person.
Ovens Supplied without Cordsets (E28M4).
NOTE: All electrical connections must only be carried
out by a suitably qualified person.
1. Remove oven rear cover panel.
Electrical
Panel
Compression
Gland
2. Bring the supply cable up
through the grommet at the
back of oven and through the
compression gland on the
electrical switchgear panel.
3. Connect the mains supply to
the appropriately marked
terminals on the terminal
block.
Grommet
NOTE:
• Fixed wiring installations must incorporate an
all-pole disconnection switch.
5
|