Mitsubishi Electronics Mitsubishi Digital Electronics Computer Hardware GT15 75ABUSL User Manual |
[DESIGN PRECAUTIONS]
CAUTION
[DISPOSAL PRECAUTIONS]
CAUTION
1. Overview
This User's Manual describes the GT15 bus connection unit
(hereafter abbreviated to the bus connection unit).
There are the following bus connection unit types.
Refer to the GT15 User's Manual for the applicable GOT.
z
Do not bunch the control wires or communication cables with
z
Dispose of this product as industrial waste.
the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100 mm
(3.94 inch) otherwise malfunctions may occur due to noise.
[TRANSPORTATION PRECAUTIONS]
CAUTION
GT15 BUS CONNECTION UNIT
User's Manual
Product
name
[INSTALLATION PRECAUTIONS]
DANGER
Model name
Description
z
Make sure to transport the GOT main unit and/or relevant unit(s)
in the manner they will not be exposed to the impact exceeding
the impact resistance described in the general specifications of
the GT15 User's Manual, as they are precision devices.
Failure to do so may cause the unit to fail.
GT15-75QBUSL
GT15-75QBUS2L
GT15-75ABUSL
GT15-75ABUS2L
QCPU (Q Mode) bus connection
Number of connectors: 1
GT15- 75QBUSL
GT15- 75QBUS2L
GT15- 75ABUSL
GT15- 75ABUS2L
z
Before mounting or dismounting this unit to or from the GOT,
always shut off GOT power externally in all phases.
Not doing so can cause a unit failure or malfunction.
QCPU (Q Mode) bus connection
Number of connectors: 2
Check if the unit operates correctly after transportation.
Bus
connection
unit
QnA/ACPU bus connection
Number of connectors: 1
CAUTION
Manuals
z
z
Use this unit in the environment given in the general
specifications of the GT15 User's Manual.
Not doing so can cause an electric shock, fire, malfunction or
product damage or deterioration.
The following shows manuals relevant to this product.
QnA/ACPU bus connection
Number of connectors: 2
Detailed Manual
Use the bus connection unit for making bus connection of the
GOT.
Select the used bus connection unit according to the
connection target and connection position.
When installing this unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the
specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to
screw or unit damage.
Thank you for purchasing the GOT1000 Series.
Manual Number
Manual name
(Type code)
Prior to use, please read both this manual and detailed
manual thoroughly to fully understand the product.
GT15 User's Manual
SH-080528ENG
(1D7M23)
<Bus connection unit selection example>
(Option)
(1) Select the bus connection unit according to the
connection target.
GOT1000 Series Connection Manual
SH-080532ENG
(1D7M26)
(Option)
[WIRING PRECAUTIONS]
DANGER
MODEL
GT15-75BUSL-U
1D7M04
QCPU (Q Mode), motion controller Q series
: GT15-75QBUSL/GT15-75QBUS2L
ACPU, QnACPU, motion controller A series
: GT15-75ABUSL/GT15-75ABUS2L
MODEL
CODE
Relevant Manuals
z
Before connecting the Bus connection cable to this unit, always
For relevant manuals, refer to the PDF manual stored within the
drawing software used.
IB(NA)-0800298-B(0504)MEE
shut off GOT power and PLC CPU power externally in all
phases.
Not doing so can cause a malfunction.
(2) Select the bus connection unit according
to the GOT connection position.
© 2004 MITSUBISHI ELECTRIC CORPORATION
CAUTION
Placed midway
Compliance with the EMC and Low Voltage
Directives
When incorporating the Mitsubishi GOT into other machinery or
equipment and keeping compliance with the EMC and low voltage
directives, refer to Chapter 4, "EMC Directives and Low Voltage
Directives" of the manual (GT15 General Description) included with
the GOT used.
The CE logo is printed on the rating plate of the GOT, indicating
compliance with the EMC and low voltage directives.
By making this product conform to the EMC directive and low
voltage instruction,it is not necessary to make those steps
individually.
: GT15-75QBUS2L/GT15-75ABUS2L
z
Insert and fit the bus connection cable into the connector of the
unit to be connected until it "clicks".
After fitting, check for lift which can cause a malfunction due to a
connection fault.
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
[STARTUP AND MAINTENANCE PRECAUTIONS]
DANGER
Placed at end
: GT15-75QBUSL/GT15-75ABUSL
GT15-75QBUS2L/GT15-75ABUS2L
z
Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or
malfunction.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".
Refer to the GOT1000 Series Connection Manual for details of
bus connection.
Product Components
The bus connection unit consists of the following items.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
CAUTION
DANGER
severe injury.
z
z
Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
Product name
Quantity
Indicates that incorrect handling may cause
CAUTION hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Do not touch the conductive areas and electronic parts of this
unit directly.
Doing so can cause a unit malfunction or failure.
Any one of GT15-75QBUSL,
GT15-75QBUS2L, GT15-75ABUSL,
GT15-75ABUS2L
1
z
Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them.Not doing so can cause unit or cable
damage due to dangling, moved or accidentally pulled cables or
can cause a malfunction due to a cable contact fault.
Seals
12
Note that the
CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the precautions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
z
z
Do not hold the cable part when unplugging any cable
connected to the unit. Doing so can cause unit or cable damage
or a malfunction due to a cable contact fault.
Always make sure to touch the grounded metal to discharge the
electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.
Warranty
2. Specifications
3. Part Names and External Dimensions
4. Installation Procedure
Mitsubishi will not be held liable for damage caused by factors found
not to be the cause of Mitsubishi; machine damage or lost profits
caused by faults in the Mitsubishi products; damage, secondary
damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
The performance specifications of the bus connection unit are
indicated below.
Refer to the used GT15 User's Manual for the general
specifications of the bus connection unit.
(1) Power off the GOT.
136.8(5.39)
(2) Remove the two expansion unit covers of the GOT.
For safe use
•
This product has been manufactured as a general-purpose part for
general industries, and has not been designed or manufactured to
be incorporated in a device or system used in purposes related to
human life.
GT15-
GT15-
GT15-
GT15-
4)
5)
Item
75QBUSL 75QBUS2L 75ABUSL 75ABUS2L
I/O
occupied
points
16 points (I/O assignment: 32 points (I/O assignment:
16 intelligent points)
•
•
Before using the product for special purposes such as nuclear
power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi.
This product has been manufactured under strict quality control.
However, when installing the product where major accidents or
losses could occur if the product fails, install appropriate backup or
failsafe functions in the system.
Special 32 points)
4)
Internal
consumed
current
0.44A
0.44A
0.12A
0.12A
(DC5V)*
Weight
0.13kg
0.14kg
0.13kg
0.14kg
(3) Fit the bus connection unit along the groove of the
GOT case.
Country/Region Sales office/Tel
U.S.A
Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon Hills, IL 60061
Tel : +1-847-478-2100
*
When the GOT power is on, the internal current consumption is
included in the current consumption of the GOT.
When the GOT power is off, the internal current is supplied from
the power supply of the PLC system.
Brazil
MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
*1
2)
Back view
1)
Tel : +55-11-5908-8331
Germany
U.K
Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Herts., AL10 8XB,UK
Tel : +44-1707-276100
3)
Italy
Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Tel : +39-039-6053344
Spain
Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
France
Mitsubishi Electric Europe B.V. French Branch
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France
TEL: +33-1-5568-5568
South Africa
Hong Kong
Circuit Breaker Industries LTD.
Tripswitch Drive, Elandsfontein Gauteng, South Africa
Tel : +27-11-928-2000
Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870
(4) Fasten the bus connection unit by tightening its
mounting screws (4 places) with tightening torgue
0.36 to 0.48 N•m.
MODEL
GT15- 75QBUSL
GT15- 75QBUS2L
GT15- 75ABUSL
GT15- 75ABUS2L
A
China
Ryoden Automation Shanghai Ltd.
3F Block5 Building Automation
Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China
Tel : +86-21-6120-0808
Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang,
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong
Kangsec-ku, Seoul, Korea
Tel : +82-2-3660-9552
Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building Singapore 159943
Tel : +65-6473-2308
F. A. Tech Co.,Ltd.
898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3
Road, Bangkpongpang, Yannawa, Bangkok 10120
Tel : +66-2-682-6522
P.T. Autoteknindo SUMBER MAKMUR
Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan
Industri/Pergudangan Jakarta - Utara 14440
Tel : +62-21-663-0833
2.3(0.09)
2.3(0.09)
3.9(0.15)
Taiwan
Korea
3.9(0.15)
Unit: mm (inch)
*1 When the GT15-75QBUSL/GT15-75ABUSL is used, only the IN
side connector is available.
Singapore
Thailand
Indonesia
India
No.
1)
Name
Description
Connector for connecting the
bus connection cable (IN side)
(5) After tightening screws, attach the supplied seals.
Bus connector (IN side)
Bus connector (OUT
side)
Connector for connecting the
bus connection cable (OUT side)
2)
3)
Messung Systems Put,Ltd.
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,
PUNE-411026, India
Tel : +91-20-712-2807
Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
For connecting the extended
connector of the GOT
Extended connector
Australia
Screw (M3 screw) for fixing the
unit to the GOT
4)
5)
Mounting screw
Rating plate
-
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.
|