Miele KM410 User Manual

Installation Instructions  
KM 400 Electric Cooktop  
KM 402 / KM 403 Fryer  
KM 408-1 Contact Grill  
KM 410 / KM 411 Electric Barbecue  
UV  
To prevent accidents and  
machine damage,  
read these instructions  
before installation or use.  
M.-Nr. 05 060 863  
Contents  
3
IMPORTANT SAFETY INSTRUCTIONS  
Note to the installer:  
Please leave this instruction book  
with the consumer for the local  
electrical inspector’s use.  
Installation  
The minimum distances given in  
these Installation Instructions must  
be observed in order to ensure safe  
operation. Failure to do so increases  
recommended  
the risk of fire.  
To prevent appliance damage, the  
cabinetry and venting hood should  
be installed first.  
The countertop must be bonded  
with heat resistant (212 °F/100 °C)  
adhesive to prevent distortion.  
The cooktops should only be  
installed in the illustrations, while  
maintaining the required safety  
distances shown. Do not install the  
cooktop between two tall cabinets, this  
is a fire hazard.  
not recommended  
a = Minimum safety distances:  
KM 400 = 2" (50 mm)  
KM 402 / 403= 2" (50 mm)  
KM 408-1 = 2" (50 mm)  
KM 410 / 411 =10" (250 mm)  
Deep fryers must not be installed  
next to gas cooktops. Gas flames  
can ignite splattering oil. A distance of  
at least 12" (305 mm) should be  
maintained between these two  
appliances.  
not allowed  
4
 
IMPORTANT SAFETY INSTRUCTIONS  
Cooktops should not be installed  
above a dishwasher, washer, dryer,  
freezer or refrigerator. The high  
temperatures radiated downwards from  
the cooktops could damage these  
appliances.  
Safety distance above the appliances  
This equipment has not been  
designed for maritime use or for  
use in mobile installations such as  
aircraft or recreational vehicles.  
However, under certain circumstances  
it may be possible for an installation in  
these applications. Please contact the  
nearest Miele Dealer or the Miele  
Technical Service Department with  
specific requirements.  
As a general rule there must be a  
minimum safety distance of at least 30  
inches (760 mm) between the top of the  
appliance and any cabinet above it, b.  
The minimum distance of combustible  
surfaces located above and to the side  
of the cooktop, c, is 18" (457 mm).  
Make sure that the power cord to  
the cooktop does not come into  
contact with any mechanical parts once  
the cooktop has been installed.  
If the cabinet manufacturer  
recommends a different distance, follow  
that manufacturer’s recommendation.  
The minimum safety distance  
between the KM 410 / KM 411 and  
the bottom of a venting hood should  
be no less than 26" (650 mm).  
If more than one appliance is  
installed beneath a hood and they  
have different minimum safety  
distances, the greater distance  
should be followed.  
Keep this instruction book in a safe  
place and pass it on to any future  
owner.  
5
 
Appliance dimensions  
KM 400 / KM 408-1  
aClamps  
bPlease allow an additional 3/4"  
(18 mm) depth below the cooktop for  
clearance of the power cord.  
6
 
Appliance dimensions  
KM 402 / KM 403  
aClamps  
7
 
Appliance dimensions  
KM 410 / KM 411  
aClamps  
8
 
Installation  
Cutting out the countertop  
Installing one or multiple appliances:  
Cut out the countertop using the  
dimensions listed in the following table.  
Number of  
cooktops  
Cut out width  
Dimension "B"  
1
2
3
4
5
6
7
10 13/16" (274 mm)  
22 1/8"  
(562 mm)  
(850 mm)  
(1138 mm)  
(1426 mm)  
(1714 mm)  
33 7/16"  
44 13  
/
16  
56 1/8"  
67 1/2"  
All Miele combisets have the same  
length and width. Make sure that there  
is enough room beneath the countertop  
to allow for the depth of the various  
appliances. When installing a KM 402 /  
KM 403 or KM 410 / KM 411 remember  
to allow clearance for the drain valve  
that will be located in the cabinet  
beneath the appliances.  
78 13/16" (2002 mm)  
The tolerance for each dimension is  
1/16" (1 mm).  
When installing more than one  
combiset cooktop, a support bar  
must be installed between the  
appliances. Install the support bars  
as shown on the following page  
before setting the appliances into  
the countertop.  
The following safety distances must be  
maintained:  
– Between the cooktop and rear wall:  
2" (50 mm).  
– Between the cooktop and side wall  
or cabinet:  
KM 400 = 2" (50 mm)  
KM 402 / 403= 2" (50 mm)  
KM 408-1 = 2" (50 mm)  
KM 410 / 411 =10" (250 mm)  
Refer to section "Important Safety  
Instructions" for further information.  
9
 
Installation  
Laying out the support bars  
and clamps  
aClamps  
cSlight gap between support bar and  
countertop.  
bSupport bars  
This illustration shows the layout for 3  
combisets, their respective support  
bars, b, and the 14 spring clamps, a,  
required for correct installation.  
If more than 3 combisets are being  
installed, add an additional 11 3/8"  
(288 mm) to the overall width of the cut  
out for each extra combiset, or use the  
table on the preceding page.  
10  
 
Installation  
Securing the support bars  
Securing the spring clamps  
d
c
Wood or Corian countertops  
Wood or Corian countertops  
^ Arrange the bars, b, as shown in the  
^ Place the spring clamps, a, as  
illustration  
shown in the illustration.  
^ Drill 1/16" (1.5 mm) pilot holes through  
the brackets and secure them using  
the supplied screws.  
^ Drill two 1/16" (1.5 mm) pilot holes for  
each clamp and secure using the  
supplied screws.  
^ Fill the gap, c, between the bars and  
the countertop using the supplied  
silicon sealant.  
Granite countertops  
Granite countertops  
For granite countertops, the spring  
clamps can be secured using  
double-sided construction adhesive.  
Do not allow the spring clamps to  
"float", they must be securely fastened.  
For granite countertops, the support  
bars, b, can be secured using  
double-sided construction tape. Do not  
allow the bars to "float", they must be  
securely fastened. Fill the gap, c,  
between the bars and the countertop  
using the supplied silicon sealant.  
The screws are not necessary for  
granite countertops.  
The screws are not necessary for  
granite countertops.  
11  
 
Installation  
Locking the appliance into  
place  
Make sure the cooktops are aligned  
correctly before setting them into the  
countertop. Once the spring clamps  
are engaged, a special tool is  
required to release the cooktop from  
the clamps.  
^ Guide the power cord through the cut  
out and connect the appliance to the  
electrical supply.  
^ Position the cooktop over the cut out.  
With a hand on each side, above the  
clamps, a, press the cooktop down,  
locking it into the spring clamps.  
Make sure that the cooktop rim lies  
flat against the countertop on all  
sides.  
12  
 
Installation  
Important  
The cooktop must not be  
permanently sealed into the  
countertop when installed.  
The sealing strip under the edge of  
the cooktop provides a sufficient  
seal for the countertop.  
If the cooktop is sealed into position,  
the countertop or the appliance may be  
damaged if the cooktop needs to be  
removed for maintenance or service.  
13  
Electrical connection  
Power supply:  
,WARNING:  
– 240 V, 60 Hz, 15 A fuse rating  
or  
Disconnect the appliance from the  
main power supply before servicing.  
To reduce the risk of electric shock,  
make sure that the appliance is  
properly grounded after installation.  
– 208 V, 60 Hz, 15 A fuse rating  
The oven is equipped with a power  
cord consisting of 3 leads. They must  
be connected to a dedicated line  
through the use of an approved  
junction box  
To guarantee the electrical safety of  
this appliance; continuity must exist  
between the appliance and an  
effective grounding system. It is  
imperative that this basic safety  
requirement be met. If there is any  
doubt, have the electrical system of  
the house checked by a qualified  
electrician. The manufacturer cannot  
be held responsible for damages  
caused by the lack, or inadequacy  
of an, effective grounding system.  
Black : connect to L1 (hot)  
Red: connect to L2 (hot)  
Green: connect to GND (ground):  
For further information, see the  
wiring diagram provided with the  
appliance.  
All electrical work should be  
performed by a qualified electrician  
in accordance with local codes and  
the:  
WARNING:  
THIS APPLIANCE MUST BE  
GROUNDED  
-
National Electrical code  
ANSI / NFPA No. 70-1481  
for USA  
or  
-
Canadian Electrical Code Part I  
(CSA Standard C 22.1)  
for Canada  
Note to the installer:  
Please leave these instructions with the  
consumer.  
14  
 
15  
Alterations rights reserved / 0705  
M.-Nr. 05 060 863 / 01  
en - US  

Intel MS 6734 User Manual
I Tech Company SLR CH400 R User Manual
JVC AV 28BT8ENB User Manual
Kambrook Convection Oven K0T630 User Manual
KitchenAid KGCC505H User Manual
Lennox Hearth AX45Q User Manual
Moffat Blue Seal G56D User Manual
Panasonic TX 68PS12A User Manual
Philips 27CI1797 User Manual
Philips Computer Monitor 40PFL4708 User Manual