KitchenAid Cooktop KFGS306V User Manual

®
Gas Built-in Cooktop  
PRODUCT MODEL NUMBERS  
INSTALLATION CLEARANCES  
KFGS306V  
KFGS366V  
KFGU706V  
KFGU766V  
A
D
Gas Supply: This cooktop is factory set for use with  
natural gas. Cooktop can be converted to LP gas.  
Conversion must be done by a qualified service  
technician. Provide a gas supply line of 3/4" (1.9 cm)  
rigid pipe to the cooktop location. A smaller size pipe on  
longer runs may result in insufficient gas supply. Pipe-  
joint compounds that resist the action of LP gas must be  
used. Do not use TEFLON® tape. With LP gas, piping or  
tubing size can be 1/2" minimum. Usually, LP gas  
suppliers determine the size and materials used in the  
system.  
B
C
F
G
K
E
J
H
N
No attempt shall be made to convert the cooktop from  
the gas specified on the model/serial rating plate for use  
with a different gas without consulting the serving gas  
supplier. See the Gas Conversion instructions provided in  
the package containing literature.  
L
I
M
Electrical: A 120 volt, 60 Hz., AC only, 15-amp fused  
electrical circuit is required. A time-delay fuse or circuit  
breaker is also recommended. It is recommended that a  
separate circuit serving only this cooktop be provided.  
A. 30" (76.2 cm) on 30" (76.2 cm) models; 36" (91.4 cm) on 36" (91.4 cm) models  
B. Combustible area above countertop (shown by dashed box above)  
C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of  
uncovered wood or metal cabinet (24" [61.0 cm] minimum clearance if bottom of  
wood or metal cabinet is covered by not less than 1/4" [0.6 cm] flame retardant  
millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm]  
stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper). If installing  
a range hood see NOTES.*  
D. 13" (33.0 cm) recommended upper cabinet depth  
E. 1-1/8" (2.8 cm)  
F. 20" (50.8 cm)  
PRODUCT DIMENSIONS  
A
B
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum  
horizontal clearances to cooktop  
C
H. Grounded outlet - Locate within 24" (61.0 cm) of right rear corner of cutout  
I. 29" (73.7 cm) on 30" (76.2 cm) models; 35-1/4" (89.5 cm) on 36" (91.4 cm) models  
J. 24" (61.0 cm) minimum countertop depth is required  
K. 2-7/8" (7.3 cm) minimum distance to rear combustible surface  
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below underside of countertop.  
Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended  
A. 30³⁄₁₆" (76.7 cm) on 30" (76.2 cm) models,  
36¹⁄₄" (92.0 cm) on 36" (91.4 cm) models  
B. 21" (53.3 cm)  
C. 3" (7.6 cm)  
M.8" (20.3 cm) minimum distance to nearest left side combustible surface.**  
N. 8" (20.3 cm) minimum distance to nearest right side combustible surface.**  
30" (76.2 cm) Cooktop Overall: M + N must equal 48" (122.0 cm) minimum + 29"  
(73.7 cm) cutout for cooktop or 77" (195.6 cm)  
36" (91.4 cm) Cooktop Overall: M + N must equal 48" (122.0 cm) minimum + 35-1/4"  
(89.5 cm) cutout for cooktop or 83-1/4" (211.5 cm)  
**M + N combined must be at least 48" (122.0 cm) minimum overall  
Example 1: M = 8" (20.3 cm) left side + N = 40" (101.6 cm) right side = 48" (122.0 cm)  
Example 2: M = 24" (61.0 cm) left side + N = 24" (61.0 cm) right side = 48" (122.0 cm)  
NOTES:  
After making the countertop cutout, some installations may require notching down the  
base cabinet side walls to clear the cooktop base. To avoid this modification, use a  
base cabinet with sidewalls wider than the cutout.  
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top  
of the drawer (or other obstruction) in base cabinet is required. The drawer depth may  
need to be shortened to avoid interfering with the regulator.  
*If installing a hood above the range, follow the hood instructions for dimensional  
clearances above the cooktop surface.  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8286867B  
06-25-08  

Iiyama AX3819UT BK User Manual
LG Electronics MU 50PZ44M User Manual
Maytag MER7662WT0 User Manual
Moffat RN8600E LS User Manual
Network Technologies CRYSTALMON CM RK17 User Manual
Panasonic Link to Cell Cellular Phone KXTG7622B User Manual
Philips 21PT4429 User Manual
Philips 190CW8FW User Manual
Philips DECT5154S User Manual
Philips HTM139 User Manual